Dillon Quick-Check Wire Tension Meter (Red) Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Dillon Quick-Check Wire Tension Meter (Red) herunter. Dillon Quick-Check Wire Tension Meter (Red) User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Quick Check “Red”

Quick Check “Red”Tension MeterUser InstructionsAWT35-501364Issue AA

Seite 2

10 Quick-Check Red User Instructions2 IntroductionThis manual covers the setup and operation of the Quick-Check Clamp Line Tensiometer from Dillon. T

Seite 3 - Table of Contents

Quick-Check Red User Instructions 11 2.2 Front Panel and KeysThe front panel of the Quick-Check is shown in Figure 2.2. The light located under the

Seite 4

12 Quick-Check Red User Instructions2.3 Important FeaturesQuick to use Attaches and removes from tensioned line in seconds. Quick-tensioning readout

Seite 5 - 1.1 About this Manual

Quick-Check Red User Instructions 13 2.4.2 External Power SupplyPlug the 4-pin end of the power supply cable into the Quick Check 4-pin connector lo

Seite 6 - 1.5 Sharp Objects

14 Quick-Check Red User Instructions3 OperationTypical operation of the Quick-Check is covered below, followed by explanations of the various display

Seite 7 - European Countries

Quick-Check Red User Instructions 15 4. Release the lever arm and you are ready to perform another measurement.Figure 3.2 Quick-Check Attached to C

Seite 8

16 Quick-Check Red User InstructionsInsure sheaves installed agree with sheaves noted in the Wire calibration. Exception: Sheaves match the wire diam

Seite 9

Quick-Check Red User Instructions 17 ModePress the Mode key to scroll through the four display modes. These are explained below:Live Tension Mode: T

Seite 10 - 2 Introduction

18 Quick-Check Red User InstructionsStorePress the Store softkey to store and add a displayed tension to the average of other entered readings. Follo

Seite 11 - 2.2 Front Panel and Keys

Quick-Check Red User Instructions 19 Setup: Setup allows the user to configure how the Quick Check stores data internally. This stored data can be

Seite 12 - 2.3 Important Features

quick check red_u_en_501364.bookDillon is part of Avery Weigh-Tronix. Avery Weigh-Tronix is a trademark of the Illinois Tool Works group of companies

Seite 13 - 2.4.2 External Power Supply

20 Quick-Check Red User InstructionsComm Port:This allows you to choose where to export the "ON PRINT" logged data. a. Cell = Setup C

Seite 14 - 3 Operation

Quick-Check Red User Instructions 21 Comm Port:This allows you to choose where to export the "ON PRINT" logged data. a. Cell = Setup

Seite 15 - 3.2 Measurement Practices

22 Quick-Check Red User InstructionsThe data will be exported to a computer via RS-232. Dillon recommends using “WedgeLink” software as a keyboard we

Seite 16 - 3.3 Softkey Functions

Quick-Check Red User Instructions 23 SetupPress the Setup softkey and you will see these choices; Power, PtFmt, Misc, About, Test and Clock. These a

Seite 17 - 7/16 6X19

24 Quick-Check Red User Instructionsl Enable Auto-Shutdown - Auto-Shutdown powers off the instrument automatically. If Yes is chosen, the following o

Seite 18

Quick-Check Red User Instructions 25 About: Press this softkey to see the following information:l Device - Press this softkey to show a list of inf

Seite 19

26 Quick-Check Red User Instructions4 Configuration Mode4.1 Accessing the Configuration ModeYou need to access the Configuration mode to perform cert

Seite 20

Quick-Check Red User Instructions 27 4. The unit is now in the Configuration mode. To see the rest of the softkeys available in this mode, press the

Seite 21

28 Quick-Check Red User InstructionsCommCommunication output (COM1) and RADIO are not supported at this time in the Quick-Check. Press the COMM key t

Seite 22

Quick-Check Red User Instructions 29 l Fixed - The unit will shutdown after the set number of minutes no matter what happens.l No Load - The unit wi

Seite 23 - Power PtFmt Misc. About Test

Quick Check Red User Instructions 3 Table of ContentsChapter 1 General Information and Warnings ...

Seite 24

30 Quick-Check Red User Instructions5 Changing SheavesAs you use the Quick-Check on different diameter cables you must change to the correct sheave s

Seite 25

Quick-Check Red User Instructions 31 6 Achieving Best Accuracy6.1 AccuracyThe Quick-Check is an instrument designed to give accuracy that typically

Seite 26 - 4 Configuration Mode

32 Quick-Check Red User Instructions6.5 Non-linearityMost three-point tension meters employ only linear characterization and have large errors at the

Seite 27

Quick-Check Red User Instructions 33 7 Troubleshooting7.1 Quick CheckProblem Possible Cause SolutionPowers on momentarily and turns off Low battery

Seite 28

34 Quick-Check Red User Instructions7.2 EDX PSUProblem Possible Cause SolutionQuick Check powers on momentarily and turns offLow batteryBad keypadRep

Seite 29

Quick-Check Red User Instructions 35 8 SpecificationsPower2 AA, common alkaline batteries. DisplayDot graphic LCD displayOperational KeysPower, Wire

Seite 30 - 5 Changing Sheaves

36 Quick-Check Red User InstructionsAvailable OptionsVaried wire sizesOperating EnvironmentSuitable for outdoor useDimensions10˝ x 23˝ x 3˝ (25 cm x

Seite 32 - 6.6 Wire Characteristics

a division ofAvery Weigh-Tronix1000 Armstrong DriveFairmont, Minnesota U.S.A.Toll-Free: (800) 368-2031Phone: (507) 238-4461Fax: (507) 238-8258www.dill

Seite 33 - 7 Troubleshooting

4 Quick Check Red User Instructions

Seite 34 - 7.2 EDX PSU

Quick-Check Red User Instructions 5 1 General Information and Warnings1.1 About this ManualThis manual is divided into chapters by the chapter numbe

Seite 35 - 8 Specifications

6 Quick-Check Red User Instructions1.1.3 Safe Handling of Equipment with Batteries1.2 Routine Maintenance1.3 Cleaning the Machine1.4 TrainingDo not a

Seite 36 - Dimensions

Quick-Check Red User Instructions 7 1.6 FCC and EMC Declarations of ComplianceUnited StatesCanadaEuropean CountriesThis equipment has been tested an

Seite 37

8 Quick-Check Red User Instructions1.7 Declaration of Conformity (Quick Check Red)

Seite 38

Quick-Check Red User Instructions 9 1.8 Declaration of Conformity (EDX PSU)

Kommentare zu diesen Handbüchern

Keine Kommentare