EDxtreme
Dynamometer and Crane Scale
User Instructions
29808-0011
Issue AE
Optional
Communicator
Seitenansicht 0
1 2 3 4 5 6 ... 49 50

Inhaltsverzeichnis

Seite 1 - EDxtreme

EDxtremeDynamometer and Crane ScaleUser Instructions29808-0011Issue AEOptionalCommunicator

Seite 2

10 EDxtreme User Instructions2 IntroductionThe EDxtremeTM (EDX) electronic dynamometer from Dillon is a force measurement load sensor and digital rea

Seite 3 - Table of Contents

EDxtreme User Instructions 11 2.1.1 EDX KeysThere are four “hard” keys and four “soft” keys. The hard keys are permanently labeled and the soft keys

Seite 4 - 4 EDxtreme User Instructions

12 EDxtreme User Instructions2.1.3 Communicator Front PanelFigure 2.2 shows the Dillon Communicator. This is a battery powered, radio-linked (or wire

Seite 5 - 1.1 About this manual

EDxtreme User Instructions 13 2.1.4 Communicator KeysThe Communicator has the same keys as the EDX but also some extra ones. They are all explained

Seite 6 - 1.2 Safe Operation

14 EDxtreme User Instructions2.2 Power On and AnnunciatorsWhen you power up the EDX you will see a display similar to the example shown on the left i

Seite 7 - 1.5 Training

EDxtreme User Instructions 15 Press the Arrow key, , to move between the two displays in Figure 2.3. In the display on the right in Figure 3, one of

Seite 8 - 1.6 Sharp objects

16 EDxtreme User Instructions3 EDX Operation3.1 Display ModesThe EDX has several display modes accessible by pressing the Mode soft key. See Figure 3

Seite 9 - European Countries

EDxtreme User Instructions 17 3.3 Force Measurement RezeroRezeroing allows the weight or load of fixturing to be invisible to the measurement. The z

Seite 10 - 2 Introduction

18 EDxtreme User Instructions4EDX SetupTo begin using the EDX, it is recommended that you set it up to suit your specific needs and equipment. You ca

Seite 11 - 2.1.2 EDxtreme Connector

EDxtreme User Instructions 19 Format #1 Current displayed value (peak or live force) plus unit of measure104.5 lbf (live force example)302.5 lbf (pe

Seite 12

© Avery Weigh-Tronix, LLC 2012 All rights reserved. No part of this publication may be reproduced, stored in an electronic retrieval system, or transm

Seite 13 - 2.1.5 Communicator Connectors

20 EDxtreme User InstructionsFormat #5 Live force, unit of measure, peak force, unit of measure. All tab separated.104.5<tab>lbf<CR> (if

Seite 14 - 2.2 Power On and Annunciators

EDxtreme User Instructions 21 4.1.3 Setup--AboutThe next soft key is the About. The About menu shows an assortment of information about your Dillon

Seite 15 - EDxtreme User Instructions 15

22 EDxtreme User InstructionsCOM2 Press this key to test COM2 in a loopback test.To perform a COMM test, the unit must be configured to use RS-232 co

Seite 16 - 3 EDX Operation

EDxtreme User Instructions 23 5 ConfigurationThe configuration menu is a group of settings that may be password protected if desired to prevent oper

Seite 17 - 3.4 Displaying Peak Force

24 EDxtreme User Instructions5.1 Configuration MenuFigure 5.3 Configuration menu5.1.1 Config--SetupThe first soft key is Setup. Press this and you a

Seite 18 - 4EDX Setup

EDxtreme User Instructions 25 5.1.3 Config--CommPress the Comm key to enable or disable radio communication and configure serial ports. To configure

Seite 19 - EDxtreme User Instructions 19

26 EDxtreme User InstructionsThe following display appears:4. Select a baud rate using the Sel keys to scroll through your choices. Choices are 1200,

Seite 20 - 4.1.2 Setup--Misc

EDxtreme User Instructions 27 5. Select a parity value using the Sel keys to scroll through your choices. Choices are none (default), odd and even.

Seite 21 - 4.1.4 Setup--Test

28 EDxtreme User InstructionsIf you enable the radio:l You are asked to enter a Radio Channel. Your EDX and Communicator must be on the same channel

Seite 22

EDxtreme User Instructions 29 3. To compensate for local gravitational differences. There are variances in gravity throughout the world. If used as

Seite 23 - 5 Configuration

EDxtreme User Instructions 3 Table of ContentspageChapter 1 General information and warnings ...

Seite 24 - 5.1 Configuration Menu

30 EDxtreme User InstructionsThe following screen is displayed:Select Yes if you only want the instrument to automatically shut down when there is in

Seite 25 - 5.1.3 Config--Comm

EDxtreme User Instructions 31 6 Communicator OperationThe Dillon Communicator is a remote display and control module designed to work with the EDxtr

Seite 26

32 EDxtreme User InstructionsThere are three soft keys on the first display and four on the second display. The soft key functions are described belo

Seite 27 - EDxtreme User Instructions 27

EDxtreme User Instructions 33 Next choice is number of EDXs in the network. Pick from 1-15Next choice, you must set the address for each EDX. Each E

Seite 28 - 5.1.5 Config--Units

34 EDxtreme User InstructionsPress ESC repeatedly to return to normal operation. If you have made changes you will be prompted to save the changes. P

Seite 29 - 5.1.6 Config--Power

EDxtreme User Instructions 35 Choice of power-up unit of measureEnable or disable lbf, kgf, N, custom unit 1 and 2Power Press this to set the follow

Seite 30 - 5.1.8 Config--Reset

36 EDxtreme User InstructionsFixed characters. Example 1:<sp><sp><sp>104.5,<sp><sp><sp><sp>lbf,<sp>&l

Seite 31 - 6 Communicator Operation

EDxtreme User Instructions 37 7 General Information7.1 Changing BatteriesTo replace discharged batteries, unscrew the battery compartment cap on the

Seite 32 - 6.2 Communicator Setup Menu

38 EDxtreme User Instructions7.4 Radio InformationThe radio technology used in the radio equipped EDxtreme and Communicator is a 2.4 GHz digital spre

Seite 33 - EDxtreme User Instructions 33

EDxtreme User Instructions 39 Place spacer on a solid surface and use a hammer to start the roll pins into the two small spacer holes. See Figure 7.

Seite 34 - 6.3 Communicator Config Menu

4 EDxtreme User InstructionsCommunicator Print Formats ... 3

Seite 35 - EDxtreme User Instructions 35

40 EDxtreme User Instructions8 Common ConfigurationsEDxtreme being used stand-alone (no RS-232 or Communicator remote)Key Settings (EDxtreme):COM1 Tr

Seite 36

EDxtreme User Instructions 41 Network Identifier: AKey Settings (EDxtreme 2):COM1 Trans Level – DisabledCOM2 Trans Level – RFRadio Channel (1-64): 1

Seite 37 - 7 General Information

42 EDxtreme User Instructions9 TroubleshootingProblem Possible Cause SolutionEDX powers on momentarily and turns offLow batteryBad keypadReplace with

Seite 38 - 7.5 Installing Spacers

EDxtreme User Instructions 43 Radio communications not working at allDead batteries. Distance is excessive, dead radio pocketBring remote closer to

Seite 39 - EDxtreme User Instructions 39

44 EDxtreme User Instructions10 Weighing and Force Measurement PracticesThe basis for all electronic force measurement or weighing is measurement of

Seite 40 - 8 Common Configurations

EDxtreme User Instructions 45 10.6 Good Force Measurement Practice

Seite 41 - EDxtreme User Instructions 41

46 EDxtreme User Instructions11 Specifications11.1 Dynamometer SpecificationsEnclosure: Designed to NEMA4X/IP55. Suitable for continuous outdoor use

Seite 42 - 9 Troubleshooting

EDxtreme User Instructions 47 11.2 Communicator SpecificationsEnclosure: Designed to NEMA 3 / IP44 with optional sleeve. Suitable for protected out

Seite 43 - EDxtreme User Instructions 43

48 EDxtreme User Instructions

Seite 45 - EDxtreme User Instructions 45

EDxtreme User Instructions 5 1 General information and warnings1.1 About this manualThis manual is divided into chapters by the chapter number and t

Seite 46 - 11 Specifications

DillonA division of Weigh-Tronix Inc.1000 Armstrong Dr.Fairmont, MN 56031 USATelephone: 507-238-4461Facsimile: 507-238-8258e-mail: dillon@weigh-tronix

Seite 47 - 11.3 Radio Specifications

6 EDxtreme User Instructions1.2 Safe OperationKeep all the following in mind as you use the EDX dynamometer.The system capacity is equal to the ratin

Seite 48

EDxtreme User Instructions 7 l Environments with high electromagnetic fields such as cranes employing electromagnets to lift metal. These induce tra

Seite 49

8 EDxtreme User InstructionsTo avoid the risk of RSI (Repetitive Strain Injury), place the machine on a surface which is ergonomically satisfactory t

Seite 50

EDxtreme User Instructions 9 United StatesCanadaEuropean CountriesThis equipment has been tested and found to comply with the limits for a Class A d